Sample Proof Pack

Review the proof objects before a live review

Inspect the evidence package behind Shadow Mode, Load Passports, capacity waterfalls, RTA traces, reserve-floor reports, and no-proof gaps before the first operator session.

What is inside

See the artifact stack before anyone asks for trust

The sample pack shows how GridNinja turns telemetry, constraints, and decisions into operator-readable proof before bounded autonomy is on the table.

Included artifacts

  • AI Data Center Load Passport
  • Capacity Waterfall
  • RTA Allow / Repair / Reject / No-Proof Trace
  • Reserve-Floor Report
  • No-Proof Gap Register
  • Utility Evidence Packet

Selected artifact

Illustrative sample · evidence chain complete

AI Data Center Load Passport

A site-specific capacity identity that summarizes proof-adjusted virtual capacity, binding constraints, freshness posture, and declared operating policy.

Who cares

Operators, hyperscalers, investors

Status

sample shape, illustrative

Caveat

Illustrative sample shape. Site-specific evidence is produced during a Capacity Audit.

Proof story

Claimed headroom becomes an exportable proof chain

Step 01

Start with claimed headroom

NO-PROOF

The story begins with a capacity claim that has not yet earned operator trust.

artifact: Observed nominal headroom

nominal_headroom

18.4 MW illustrative

proof_posture

claim only

Step 02

Bind every active constraint

REPAIR

Power, cooling, reserve, workload, and telemetry trust each reduce unsupported headroom.

artifact: Constraint braid

binding

reserve floor + telemetry trust

capacity_after

5.8 MW illustrative

Step 03

Run the RTA decision

ALLOW

The runtime assurance layer allows, repairs, rejects, or returns no-proof before authority expands.

artifact: RTA trace

decision

ALLOW after repair

authority

solver + RTA gate

Step 04

Export the proof pack

ALLOW

Accepted capacity becomes an inspectable proof object, not a hidden dashboard claim.

artifact: Proof Pack

artifact

Load Passport + ledger + evidence packet

proof_root

8f4c...91a

Capacity Waterfall

Nominal headroom reduced to proof-adjusted capacity

Illustrative sample · evidence chain completeALLOW

illustrative

accepted headroom

5.8 MW

proof_root: 8f4c...91a

Observed nominal headroom

NO-PROOF
18.4 MW

The starting claim before proof. Illustrative Atlas-3 scenario.

inspect proof hint

capacity after: 18.4 MW

Electrical constraint

REPAIR
-3.7 MW

Feeders, transformers, PQ, and ramp behavior remove unsafe headroom.

inspect proof hint

capacity after: 14.7 MW

UPS/BESS reserve floor

REPAIR
-3.5 MW

Resilience reserve remains protected before flexibility is considered.

inspect proof hint

capacity after: 11.2 MW

Cooling and water margin

REPAIR
-2.3 MW

Thermal and water posture reduce usable AI capacity in constrained intervals.

inspect proof hint

capacity after: 8.9 MW

SLA/workload posture

REPAIR
-1.8 MW

Latency, immovable workloads, and tenant commitments stay inside policy.

inspect proof hint

capacity after: 7.1 MW

Telemetry trust discount

NO-PROOF
-1.3 MW

Stale or incomplete evidence becomes a no-proof discount.

inspect proof hint

capacity after: 5.8 MW

Proof-adjusted safe capacity

ALLOW
+5.8 MW

The illustrative accepted answer, not a guaranteed GridNinja outcome.

inspect proof hint

capacity after: 5.8 MW

Synthetic illustrative scenario—not a customer or production result.

Load Passport

A capacity identity for one AI data center site

Illustrative sample · evidence chain complete

Source evidence

Site Identity

Telemetry boundary, site role, and declared operating policy.

Telemetry source

Site registry + read-only connector manifest

Freshness

manifest sampled T-00:09

Proof row

Verifiedlp.site_identity.row_001

site_identity.json
connector_manifest.json

Sample download

Illustrative sample · evidence chain complete

Review the evidence package on your own terms

Use the sample bundle to inspect the decision path, envelope margins, and rollback posture before you commit to a live review.

Scope

Shadow Mode baseline and Load Passport

Decision path

Allow, repair, reject, no-proof

Evidence

Waterfall, ledger, reserve floor, utility packet

Deterministic progress

Compiling event tape...

Checking telemetry trust...

Running solver verification...

Applying RTA policy...

Writing proof row...

T+00:03

verified

event tape compiled

4,921 ordered rows staged for replay

T+00:09

untrusted

untrusted telemetry isolated

rack group RG-17 held as dashed no-proof evidence

T+00:18

locked

proof root locked

same tape, topology, and policy produce 8f4c...91a

T+00:19

written

receipt written

edge-004921 recorded read-only

Example log

A short log should explain the operating decision

The proof pack should let a reviewer understand what changed, why it changed, and what margin remained without opening a dashboard.

Utility evidence packet

Planning value without pretending to be a utility approval

GridNinja translates local proof into evidence utilities and energy market coordinators can inspect. It does not replace interconnection studies, tariff requirements, or operator authority.

  • Flexible MW by interval
  • Ramp-rate envelope
  • Safe reconnection envelope
  • Telemetry confidence and exceptions
  • No-proof gaps and remediation owners

Review checklist

  • Binding constraint, remaining margin, and reason code are visible.
  • The action bundle is written in operator language, not model jargon.
  • No-proof gaps are treated as safety outcomes, not hidden uncertainty.
  • Replay, rollback, and audit evidence are readable without a dashboard.

Proof before autonomy

Use the sample pack to decide whether the site is ready for Shadow Mode

If the artifact structure is useful, request a Capacity Audit, inspect the demo flow, or request a Load Passport sample mapped to your stakeholder question.